Cherskii, Russia

Pleistocene Park Station - Wiring Diagram

This table is automatically updated when the station CRBASIC program is changed.

SDM INPUT
SDM-C1 SDMHUB Data (green, green): SDM to tower, and SDM to SDM rel
SDM-C2 SDMHUB Clock (white, white)
SDM-C3 SDMHUB Enable (red, red)
G SDMHUB reference (black, black)
SDMHUB (clear, clear
ANALOG INPUT
1H,1SE (MUX) COMM ODD HIGH (red)
1L,2SE (MUX) COMM ODD LOW (black)
gnd (MUX) GROUND (clear)
2H,3SE CNR 4 thermistor signal (white) *PRT wires on T radiometer c
2L,4SE Setra278 (yellow)
gnd setra purple, IRR-P (blue)
3H,5SE CNR 4 downwelling shortwave radiation signal (red)
3L,SE6 CNR 4 downwelling shortwave radiation signal reference (blue
gnd CNR 4 shield (clear)
short jumper wire to 3L
4H,SE7 CNR 4 upwelling shortwave radiation signal (white)
4L,SE8 CNR 4 upwelling shortwave radiation signal reference (black)
gnd short jumper wire to 4L
5H,9SE CNR 4 downwelling longwave radiation signal (gray)
5L,10SE CNR 4 downwelling longwave radiation signal reference (yello
gnd short jumper wire to 7L
6H,11SE CNR 4 upwelling longwave radiation signal (brown)
6L,12SE CNR 4 upwelling longwave radiation signal reference (green)
gnd short jumper wire to 8L
7H,13SE Flow meter signal (yellow)
7L,14SE OPEN
gnd OPEN
8H,15SE LI-840 CO2 signal (red)
8L,16SE LI-840 CO2 ground (black)
gnd OPEN
9H,17SE LI840 H20 signal (blue)
9L,18SE LI840 H20 signal (white)
gnd
10H,19SE HFP01SC #1 signal (white): SOIL HEAT FLUX PLATE #1
10L,20SE HFP01SC #2 signal (white): SOIL HEAT FLUX PLATE #2
gnd HFP01SC #1,#2 sig. ref.(greenx2),HFP01SC #1,#2 shield (clear
11H,21SE HFP01SC #3 signal (white): SOIL HEAT FLUX PLATE #3
11L,22SE HFP01SC #4 signal (white): SOIL HEAT FLUX PLATE #4
gnd HFP01SC #3,#4 sig. ref.(greenx2),HFP01SC #3,#4 shield (clear
12H,23SE CS616 #1 signal (green): SOIL MOISTURE PROBE1
12L,24SE CS616 #2 signal (green): SOIL MOISTURE PROBE2
gnd OPEN
13H,25SE HFP01SC #1 heater resistor signal (yellow): SOIL HEAT FLUX P
13L,26SE HFP01SC #2 heater resistor signal (yellow): SOIL HEAT FLUX P
gnd HFP01SC #1, #2 HR sig. ref. (purplex2),HFP01SC #1, #2 heat.
14H,27SE HFP01SC #3 heater resistor signal (yellow): SOIL HEAT FLUX P
14L,28SE HFP01SC #4 heater resistor signal (yellow): SOIL HEAT FLUX P
gnd HFP01SC #3, #4 HR sig. ref. (purplex2),HFP01SC #3, #4 heat.
PULSE PORTS
P1 TE525 Signal (black): RAIN GAUGE
P2 RMYoung WS
gnd TE525 Signal Reference (white),TE525 Shield (clear)
EXC. CHANNELS
VX1 107_L_1 (black) (Tpanel and Temp_grad 107s)
VX2 IR R-P (white)
VX3 CNR 4 thermistor excitation (red) *NOTE -PRT wires on T radi
VX4 RMYoung red
CONTROL PORTS
C1 MUX RESET (red)
G MUX GROUND(red)
C2 MUX CLOCK (red)
G
C3 SR50A SDI-12 I/O (green)
G SR50A Shield (clear)
(S R50A,white -- NOT USED)
C4 CS616 #1, #2 power control (orange X 2)
G CS616 #1, #2 shield (clear X 2)
C5
G
C6 Setra278 (green)
G Setra278 (clear)
C7 open
G
C8 Pump control relay, lower enclosure, + (red)
G Pump relay (black)
AM 16/32 MUX
COM ODD H DL 1H
COM ODD L DL 1L
COM GROUND DL Gnd
Res DL C1
Clk DL C2
Gnd DL G
12V DL 12V
1H TCAV #1 signal (purple): TYPE E THERMOCOUPLE
1L TCAV #1 shield (clear),TCAV #1 sig. ref.(red)
gnd
2H TCAV #2 signal (purple): TYPE E THERMOCOUPLE
2L TCAV #2 shield (clear),TCAV #2 sig. ref.(red)
gnd
3H LI190SB Signal+ (red): PAR SENSOR
3L LI190SB Signal- (black) *MAY NEED JUMPER TO SIG.GROUND!!
gnd LI190SB shield (clear)
4H LI190SB Signal+ (red): PARUP SENSOR
4L LI190SB Signal- (black)
gnd LI190SB shield (clear)
5H HMP45C temperature signal (yellow): TEMPERATURE/RH (Upper Le
5L HMP45C relative humidity signal (blue): TEMPERATURE/RH (Uppe
gnd HMP45C signal reference (white),HMP45C shield (clear)
6H HMP45C temperature signal (yellow): TEMPERATURE/RH (Lower Le
6L HMP45C relative humidity signal (blue): TEMPERATURE/RH (Lowe
gnd HMP45C signal reference (white),HMP45C shield (clear)
7H IRR-P signal(red)
7L I RR-P ref (black)
gnd IR R-P shield (clear)
8H 1 07-L_1 (PanelT_1) (red)
8L o pen
gnd 107-L_1 (purple,clear)
9H IRRP SE voltag
10H RMYoung WD SE voltage
11H 107 Temp_grad_1
gnd shield
12H 107 Temp_grad_2
gnd shield
13H 107 Temp_grad_3
gnd shield
14H 107 Temp_grad_4
gnd shield
D.L.POWER OUT
12V HMP45C power (red)
CS616 #1 power (red) : SOIL MOISTURE PROBE1
CS616 #2 power (red) : SOIL MOISTURE PROBE2
SR50A Power (red)
MUX Power (red)
Setra 278 (red)
G HMP45C power reference (black)
CS616 #1 signal reference (black)
CS616 #2 signal reference (black)
SR50A Power Ground (black)
MUX Power (black)
Setra278 (black)
5V Flow meter power (red)
G Flow meter ground (blue)
SW12-1 HFP01SC #1 heater (red) : SOIL HEAT FLUX PLATE1
HFP01SC #2 heater (red) : SOIL HEAT FLUX PLATE2
HFP01SC #3 heater (red) : SOIL HEAT FLUX PLATE3
HFP01SC #4 heater (red) : SOIL HEAT FLUX PLATE4
G HFP01SC #1 heater reference (black)
HFP01SC #2 heater reference (black)
HFP01SC #3 heater reference (black)
HFP01SC #4 heater reference (black)
Terminal Block POWER (in logger enclosure)
POS CR3000 (red)
SDM HUB, to tower top (red)
Power to Profile system, lower enclosure, (red)
Flowmeter Power + (red)
NEG CR3000 (black)
SDM HUB, to tower top (black)
Power to Profile system, lower enclosure, (blue
Flowmeter Power - (blue)
CO2 Profile sys tem wiring, lower enclosure
SDM-8 relay Power shared in SDM wire to logger
Pos (blue), Neg (black)
SDM C1 (green), SDM C2 (white), SDM C3 (red)
Terminal Block POWER (in lower enclosure)
POS Pump relay, + (red), then red wire to pump
LI840 + (red)
Positive from Logger box (red)
NEG Pump neg, to pump (black
LI840 - (blue)
Negative from Logger box (blue)
Connection box for CH2044 radiation instruments on ground level by tower
Wiring diagram for extension cables (sensor wire color followed by extensio
(C.Edgar Sept 2011)
8 wire cable, b lack elec tape:
Sensor<->Extens ion wire
HMP45C
White = white
Blue = blue
Yellow = yellow
Clear = brown
PAR_up
Black = black
Red = red
Clear = green
*Purple wire no t used
8 wire cable, N O black elec tape:
Sensor<->Extens ion wire
SR50 snow senso r
Green = black
White = not use d
Clear = brown
IRR-P
Red = red
Black = yellow
Clear = blue
Purple = purple
Green = green
White = white
4 wire cable
POWER
Red = positive 12V DC from logger
Blue = negative 12V from logger
*green AND y ellow NOT used
***ENDREAD